CloudEngine S310-24T4S
switches ini adalah switches dengan akses Layer 3 generasi baru yang dikembangkan oleh Huawei. Mereka dapat digunakan dalam berbagai skenario aplikasi, seperti akses dan agregasi jaringan kampus.
These switches are new-generation Layer 3 access switches developed by Huawei. They can be used in various application scenarios, such as campus network access and aggregation.
Specifications Switch Huawei S310-24T4S :
Basic Information
Part Number : 98012202
Model : S310-24T4S
Description : S310-24T4S(24*10/100/1000BASE-T ports, 4*GE SFP ports, AC power)
Technical Specifications :
Height [mm] : 43.6 mm
Depth [mm] : 220.0 mm
Wide [mm] : 442.0 mm
Chassis height [U] : 1
Weight with packaging : 3.44 (7.58)
Weight without packaging : 2.32 (5.11)
Maximum power consumption [W] : 34.04
Typical power consumption [W] : 26.37
Maximum heat dissipation [BTU/h] : 116.15
Heat dissipation mode : Air cooling for heat dissipation, intelligent fan speed adjustment
Typical heat dissipation [BTU/h] : 89.98
Power supply mode : AC built-in
Input voltage range [V] : AC input: 90–290 V AC; 45–65 Hz
Rated input voltage [V] : AC input: 100–240 V AC; 50/60 Hz
Maximum input current [A] : 0.8 A
Number of power slots : 0
Number of card slots : 0
Memory : 2 GB
Flash memory : 1 GB in total. To view the available flash memory size, run the display version command.
Redundant power supply : Not supported
Types of fans : Built-in
Noise at normal temperature (acoustic pressure) : 35
Noise at normal temperature (acoustic power) : 47
Airflow direction : Air intake from left and front, air exhaustion from right
Restriction on the operating temperature variation rate : When the altitude is 1800–5000 m (5906–16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).
Devices cannot start when the temperature is lower than 0°C (32°F).
Long-term operating temperature : -5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5905.44 ft.)
Storage temperature : –40°C to +70°C (–40°F to +158°F)
Long-term operating relative humidity [RH] : 5% RH to 95% RH (non-condensing)
Storage altitude : 0-5000 m (0-16404 ft.)
Long-term operating altitude : 0–5000 m (0–16404 ft.)
MTBF [year] : 70.75
MTTR [h] : 2
Availability : >0.99999
Maximum number of physical ports on the entire device : 28
Maximum number of 100GE ports : 0
Maximum number of 40GE ports : 0
Maximum number of 25GE ports : 0
Maximum number of 10GE ports : 0
Maximum number of GE ports : 28
Maximum number of FE ports : 24
1000M electrical interface : 24
1000M optical interface : 4
USB : Not supported
Console port : RJ45
Eth Management port : Not supported
Service port surge protection : Common mode: ±7 kV
Power supply surge protection : Differential mode: ±6 kV; common mode: ±6 kV
RPS input : Not supported
PoE : Not supported